Representative Project Experience-
Structural
Hyatt Expansion, San Diego, California:
Structural
Engineering Design Services for the 34-story Hyatt Hotel,
San Diego consisting of approximately 530,000 square feet
in additional size and 446 feet in height. The complex includes
a 30,000 square foot ballroom, supporting a terrace and pool;
a 34,000 square foot galleria below the ballroom and 100,000
square feet of meeting rooms and miscellaneous support areas.
The structural system consists of concrete shear walls around
the elevator core, complimented with a 6-story bracing system
and special moment frame. |
|
Marriott
Courtyard Hotel, San Diego, California:
Structural Engineering Final Design Services for the seismic
upgrade of the 13-story steel frame Marriott Hotel with
a cast-in-place, pan-joist floor system. Services also included
a general upgrade of the existing lateral system to meet the
minimum required lateral force, based on the state historical
code. Lateral reinforcement of the cupola frame; the addition
of a full height north exist stair and miscellaneous incidental
structural improvements including a new entry canopy and the
infill of existing floor openings and creation of new localized
floor openings. This project received Recognition of Outstanding
Achievement in the Field of Historic Preservation from the California
Preservation Foundation Design Awards 2000.
|
|
Inmate Reception Center, San Diego, California:
Structural
Engineering Design services for the design of the ten-story
(equivalent to a seventeen-story) cast-in-place concrete Inmate
Reception Center consisting of approximately 340,000 square
feet with an access pedestrian bridge from the existing inmate
facility across the street.
|
|
Carrillo Hotel, Santa Barbara, California:
Structural
Engineering Design Services for a 7-story post-tension Carrillo
Hotel complex which includes approximately 104,000 SF
on a mat foundation system with two levels of parking underground.
The underground parking levels are connected to an existing
parking structure with a new tunnel.
|
|
San
Diego Chargers Training Facility, San Diego, California:
Structural
Engineering Design Services for the two-story, multi-use, steel
frame San Diego Charges Training Facility consisting
of approximately 71,000 square feet. |
|
Grand Central Arts Center Mixed-Use Facility, Santa Ana,
California:
Structural
Engineering design services for the seismic retrofit of the
2-story under-reinforced concrete and masonry Grand Central
Arts mixed-use facility with a partial basement. |
|
Village
Walk Housing, Downtown San Diego, California:
Structural
Engineering Design services for Village Walk Housing's
77 condominium units, with below-grade parking. |
|
UCSD
Social Sciences Building, San Diego, California:
Structural
Engineering design services for the UCSD five-story steel
frame graduate studies building. The project contains over 60,000
square feet utilizing composite steel and concrete construction
over a caisson foundation system. |
|
Cesar
Chavez Elementary School, San Diego, California:
Structural
Engineering design services for Cesar Chavez Elementary School
consisting of a steel, masonry and wood framed school complex
with 18 classrooms comprising two single-story buildings and
one, two-story building with a net building area of approximately
48,000 square feet. |
|
Irvine Fire Station No. 6, Irvine, California:
Structural
Engineering Design Services for a single-story wood framed Fire
Station with three apparatus bays of approximately 9,000
SF. |

|
|